| Serie |
Amp. |
Polen |
AIC* |
Vac |
Vdc |
| ATR 11 |
0,5-16 |
1 |
1000 |
240 |
50 |
| ATR 20 |
2,5-20 |
1 |
1000 |
240 |
50 |
Hydraulisch magnetisch
| Serie |
Amp. |
Polen |
AIC* |
Vac |
Vdc |
| SAS |
0,1-15 |
1 |
500 |
250 |
50 |
| SAR |
0,1-30 |
2 |
500 |
250 |
50 |
| SNAPAK |
0,10-30 |
2 |
1000 |
250 |
50 |
| AP |
0,05-20 |
3 |
1000 |
240 |
50 |
|
IEG |
0,05-50 |
6 |
7,500 |
250 |
80 |
| LEG |
0,05-30 |
2 |
5000 |
250 |
- |
| IEL |
0,05-100 |
6 |
7,500 |
480 |
300 |
| LEL |
0,05-100 |
3 |
50,000 |
250 |
80 |
| IULP |
125-300 |
1 |
50,000 |
- |
80 |
| IALR |
0,05-70 |
4 |
7,500 |
415 |
80 |
| 209 |
0,10-125 |
6 |
10,000 |
600 |
160 |
| JAE |
100-1200 |
6 |
100,000 |
240 |
250 |
*AIC = max. verbreek capaciteit Vac/Vdc = max. beschikbare spanning
Thermisch
|
- Snap action mechanism.
- Push-to-reset actuation.
- Max Poles: 1
- Current & Voltage Ratings:
ATR 11
0.50 to 16 amps at 240Vac
0.50 to 16 A at 50Vdc
0.50 to 12 A at 24Vdc (VDE)
ATR20
2.50 to 20 A at 240Vac, 50/60Hz
2.50 to 20 A at 50Vdc
- Interrupting Capacity: 1000 A
- Approvals:
UL Recognized, CSA Certified
VDE Approved, CE Compliant, TÜV
|

 |
Hydraulisch magnetisch terug
SAS/SUS/SES Serie Download: brochure |
- Smallest 15A rated circuitprotector
- Reinforced insulation and an electromagnetic safety system.
- Max Poles: 1
- Current & Voltage Ratings:
0.1 to 15.0 A, 125VAC, 50/60Hz
0.1 to 15.0 A, 250VAC, 50/60Hz
0.1 to 15.0 A, 32VDC
0.1 to 15.0 A, 50VDC
- Interrupting Capacity: 500 A
- Approvals:
UL Recognized, CSA Certified
VDE Approved
|
 |
SAR/SUR/SER/Serie Download: brochure |
- Smallest 20A rated circuitprotector
- Reinforced insulation and an electromagnetic safety system.
- Max Poles: 2
- Current & Voltage Ratings:
0.1 to 20.0 A, 125VAC, 50/60Hz
0.1 to 15.0 A, 250VAC, 50/60Hz
0.1 to 15.0 A, 32VDC
0.1 to 30.0 A, 50VDC
- Interrupting Capacity: 500 A
- Approvals:
UL Recognized, CSA Certified
VDE Approved
|
 |
Snapak Serie Download: brochure |
- SPST or DPST.
- Toggle, rocker, push-pull, push-to-reset. Patented snap action mechanism. Illuminated rocker handle. Aesthetically pleasing for front panel mounting
- Max Poles: 2
- Current & Voltage Ratings:
0.10 to 7.5 A, 50Vdc & 250VAC
0.10 to 30 A, 32Vdc
0.10 to 30 A, 120Vac
0.10 to 25 A, 120/240Vac (2 p.)
0.10 to 20 A, 250Vac at 500AIC
0.10 to 20 A, 65Vdc, 500AIC (2 p.)
- Interrupting Capacity: 1,000 A
- Approvals:
UL489A Listed (CPP, CPR, CR)
UL Recognized, CSA Certified
TÜV Approved, VDE Approved
CE Compliant, CCC Approved
|
 |
terug
AP/UP/AP-MIL Serie Download: brochure |
- QPL to MIL-PRF-39019
Sealed protection.
- Can withstand 100G shock.
Tolerates 10G vibration from 10 to 2000Hz under full load.
Ideal for use in Class 1, Div 2, Groups A, B, C, D hazardous locations.
- Max Poles: 3
- Current & Voltage Ratings:
AP Ratings:
0.05 to 20 A, 240Vac, 50 Vdc
UP Ratings:
0.05 to 20 A at 50Vdc
0.05 to 15 A at 120Vac
0.05 to 7.5 A at 240Vac
- Interrupting Capacity:
AP Ratings:
500 A at 50Vdc & 120Vac
300 A at 240Vac
UP Ratings:
1000 A at 50Vdc & 240Vac
- Approvals:
QPL to MIL-PRF-39019
UL Recognized (UP type only)
FM Approved (UP type only)
|
 |
IAG/IUG/IEG/CEG Serie Download: brochure |
- Multi-pole versions, multi or single handle.
- Options: Auxiliary switch, snap-in mounting, mid-trip handle, dual frequency.
- IEG version meets IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805
- Max Poles: 6
- Current & Voltage Ratings:
0.05 to 50 A, 80Vdc
0.05 to 50 A, 240Vac, 50/60Hz
0.05 to 30 A, 277Vac, 50/60Hz 0.05 to 30 A, 250Vac, 400 Hz
0.05 to 30 A, 125Vac, 50/60 Hz
1.0 to 30 A, 120/240Vac, 50/60 Hz
- Interrupting Capacity:
5,000 A, 240Vac, 50/60 Hz
1,500 A, 240Vac, 400 Hz
7,500 A, 80Vdc (IEG)
5,000 A, 80Vdc (CEG)
2,000 A, 250Vac, 50/60 Hz (VDE)
4,000 A, 80Vdc, (VDE)
5,000 A, 125Vac, 50/60 Hz (LEG)
5,000 A, 120/240Vac,
50/60 Hz (LEG)
- Approvals:
UL 489 Listed (LEG)
UL 489A Listed (CEG)
UL Recognized, CSA Certified
VDE Approved (IEG, CEG, LEG)
CE Compliant, CCC Approved
UL 1500 Certified
QPL to MIL-PRF-55629
|
 |
terug
LEG Serie Download: brochure |
- Multi-pole versions, multi or single handle Options: Auxiliary switch, snap-in mounting, mid-trip handle.
- Max Poles: 2 poles with a max of three sections.
- Current & Voltage Ratings:
0.05 - 30 A, 125VAC, 50/60 Hz
1.0 - 30 A 120/240Vac, 50/60 Hz
0.1 - 30 A, 250 Vac, 50/60Hz VDE
- Interrupting Capacity:
5000 AIC UL listed
2000 AIC VDE
- Approvals: UL 489 Listed
UL Recognized, CSA Certified, VDE Approved, UL 1500 Certified, CE Compliant, CC Approved
|
 |
IAL/IUL/IEL Serie Download: brochure |
- Multi-Pole versions with multi or single handle.
- Options: Auxiliary switch, snap-in mounting, mid-trip handle, dual frequency.
- IEL versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805.
- Dual frequency delay options
- Max Poles: 6
- Current & Voltage Ratings:
0.05 to 100 A at 65 VDC
0.05 to 70 A at 80 VDC
0.05 to 50 A at 250 VDC
0.05 to 50 A at 300 VDC
0.05 to 70 A at 240 VAC, 50/60 Hz
0.05 to 50 A at 277 VAC, 50/60 Hz 0.05 to 50 A at 277/480 VAC
0.05 to 50 A at 250 VAC, 400Hz
- Interrupting Capacity:
5,000 A, 250Vac, 50/60 Hz
1,500 A, 250Vac, 400 Hz
7,500 A, 80Vdc
2,000 A, 240Vac, 50/60Hz VDE
2,000 A, 415Vac, 50/60Hz VDE
4,000 A, 80Vdc (VDE)
1,200 A, 277/480Vac
5,000 A, 250VDC
1,000 A, 300VDC
- Approvals:
UL Recognized, CSA Certified
VDE Approved (IEL)
CE Compliant (IEL)
CCC Approved, UL 1500 Certified
QPL to MIL-PRF-55629
|

|
terug
LEL Serie Download: brochure |
- Multi-pole versions with multi or single handle.
- Options: Auxiliary switch, snap-in mounting, mid-trip handle, dual frequency.
- LEL versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805.
- Max Poles: 3
- Current & Voltage Ratings:
0.05 to 100 A, 80Vdc
0.05 to 50 A, 125Vac, 50/60Hz
0.05 to 80 A, 120/240Vac 50/60Hz 0.10 to 100 A, 80Vdc (VDE)
0.10 to 50 A, 250Vac (VDE)
- Interrupting Capacity:
50,000 A, 80Vdc
5,000 A, 120/240Vac, 50/60Hz
2,000 A, 80Vdc (VDE)
2,000 A, 250Vac, 50/60Hz VDE
10,000 A, 125Vac 120/240Vac
- Approvals:
UL 489 Listed, CSA Certified
VDE Approved, CCC Approved
CE Compliant
|
 |
IULP/LELP/CELP Serie Download: brochure |
- Unique, parallel current sensing design. Compact size, high current capacity.
- Options: Auxiliary switch, mid-trip handle.
- Max Poles: 1 (size 2 or 3 poles)
- Current & Voltage Ratings:
-two paralleled poles @ 80Vdc;
125 A, 150 A, 175 A, 200 A.
-three paralleled poles @ 80 Vdc;
251 to 300 A
- Interrupting Capacity:
- 50,000 A, 80Vdc (up to 100 A) 50,000 A, 65Vdc (up to 200 A)
10,000 A, 80Vdc (>100 A)
- Approvals:
UL 489 Listed, UL 489A Listed
CSA Certified
|
 |
IALR/IULR/IELR Serie Download: brochure |
- Designed to mount on standard 35mm DIN rails.
- IELR versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805.
- Max Poles: 4
- Current & Voltage Ratings:
0.05 to 70 A, 80Vdc
0.05 to 70 A, 250Vac, 50/60Hz
0.1 to 50 A, 80Vdc (VDE)
0.1 to 50 A, 250Vac, 50/60 Hz VDE
0.1 to 30 A, 415Vac, 50/60 Hz VDE
- Interrupting Capacity:
7,500 A, 80 Vdc
5,000 A, 250Vac, 50/60Hz
2,000 A, 277Vac, 50/60Hz
2,000 A, 250Vac, 50/60Hz VDE
2,000 A, 415Vac, 50/60Hz VDE
4,000 A, 80Vdc VDE
- Approvals:
UL Recognized, CSA Certified
VDE Approved (IELR)
CE Compliant
|
 |
209/219/229/279 Serie Download: brochure |
- Front-or-back connected terminals
- Complies with International Requirements
279 style complies to UL 489A
249 Power Selector Breaker System is listed as a Branch Circuit Breaker per UL 489
E-Frame style model complies with UL standard 489
- Max Poles: 6
- Current & Voltage Ratings:
0.10 to 100 A, 160Vdc
0.10 to 125 A, 125Vdc
0.10 to 77 A 600Vac
0.10 to 100 A, 347/600Vac
0.10 to 100 A, 125Vdc, 240/415Vac VDE
- Interrupting Capacity:
5,000 A; 10,000 A; 4,000 A (VDE)
- Approvals:
UL489 Listed, UL489A Listed (279)
UL Recognized, CSA Certified
VDE Approved, UL 1500 Certified
CCC Approved, CE Compliant
|
 |
JAE/JRE/JTE/JLE Download: brochure |
- F-Frame style compl. with UL 489
Various terminal options for design flexibility. Options: Auxiliary switch, mid-trip handle
Reduced voltage drop
- Max Poles: 6
- Current & Voltage Ratings:
UL 489:
100 to 250 A, 160Vdc
100 to 250 A, 65Vdc
100 to 250 A, 125/250Vdc (2 pole)
100-250 A, 240Vac
UL 489A (paralleled poles):
275 - 800 A,
275 - 1200 A, 65Vdc
- Interrupting Capacity:
10,000 A, 160Vdc
10,000 A, 125/250Vdc
65,000 A, 65Vdc
10,000 A-10,000 A, 240Vac
100,000 A, 65Vdc
- Approvals:
UL 489 Listed, UL 489A Listed
UL Recognized, CSA Certified
VDE approved, CCC Approved
CE Compliant
|
 |
terug |


Sensate Airpax Circuit Breaker zijn uiterst nauwkeurig en betrouwbaar.
De basis vormt het Hydraulisch Magnetisch principe, waarbij het schakelpunt niet beïnvloed wordt door de temperatuur,
tussen – 40º en + 85ºC.
Dus 16 Amp. is 16 Amp.!
Meer weten over dit principe? Klik HIER.
Om tegemoet te komen aan de vraag naar nog kleinere en prijs gunstigere uitvoeringen, zijn er de Airpax thermische modellen ATR.
Er is een ruime keus aan configuraties, handel opties en accessoires. Treft u niet aan wat u zoekt? Neem contact op met ons en wij
helpen u graag verder.
Militaire toepassingen.
Diverse uitvoeringen voldoen aan MIL specificaties, zoals de series AP, IAG en IAL
Heeft u een Nato Stock Nummer (NSN)?
Klik HIER voor het zoeken naar het equivalent.
Via de volgende links vindt u achtergrond informatie over genoemde MIL specificaties. M39019
M55629 |